ADC

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in ADC Online
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Roessingh, A S d. B.
Right arrow Articles by Guignard, J-P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Roessingh, A S d. B.
Right arrow Articles by Guignard, J-P
Arch Dis Child 2001;85:155-157 ( August )

Article

Dipstick measurements of urine specific gravity are unreliable A S de Buys Roessingh, A Drukker, J-P Guignard

Renal Unit, Department of Paediatrics, University Medical Centre (CHUV), CH-1011 Lausanne, Switzerland

Correspondence to: Prof. Guignard Jean-Pierre.Guignard{at}chuv.hospvd.ch

Accepted 21 March 2001

AIM---To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG).
METHODS---Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three different methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick).
RESULTS---The correlations between the visual U-SG dipstick measurements and U-SG determined by a refractometer and the comparison of Clinitek®-50 dipstick U-SG measurements with U-Osm were less than optimal, showing very wide scatter of values. Only the U-SG refractometer values and U-Osm had a good linear correlation. The tested dipstick was unreliable for the bedside determination of U-SG, even after correction for U-pH, as recommended by the manufacturer.
CONCLUSIONS---Among the bedside determinations, only refractometry gives reliable U-SG results. Dipstick U-SG measurements should be abandoned.


Keywords: urine specific gravity; dipstick urinalysis


© 2001 by Archives of Disease in Childhood






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
ARCH DIS CHILD FETAL NEONATAL ED ED PRACTICE
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2001 BMJ Publishing Group Ltd & Royal College of Paediatrics and Child Health